Double-Stage RO + EDI Ultrapure Water Solution for Semiconductor Packaging & Testing Plants

Date: 2026-07-09 Categories: electronics industry Views: 73

1. Project Overview

Project Scale: Packaging & testing workshop with hourly water consumption of 15 m³/h. Processes include wafer dicing rinsing, pre-molding cleaning and pad cleaning. The production process imposes strict control on resistivity, TOC and trace metal ions; water quality fluctuations may cause chip leakage and packaging defects.

2. Designed Water Quality Standards (25℃)

Resistivity: 15~17 MΩ·cm

TOC ≤15 ppb

Single heavy metal ion ≤0.5 ppb

Particulates ≥0.1 μm: ≤5 particles per mL

Dissolved oxygen ≤25 ppb

3. Full Process Flow

Raw Water→Multi-Media Filter→Activated Carbon Filter→Sodium Ion Softener→Dosing Unit→5μm Security Filter→1st-Stage Reverse Osmosis→2nd-Stage Reverse Osmosis→EDI Feed Water Tank→EDI→Vacuum Degassing Tower→185/254 Dual-Wavelength TOC UV→Ultrapure Water Storage Tank→0.1μm Terminal Filter→Packaging Cleaning Station

4. System Highlights

Two-stage reverse osmosis performs pre-desalination to greatly reduce salt content of EDI influent and lower membrane stack load. EDI realizes continuous desalination via electric field, eliminating traditional acid-base mixed beds and cutting hazardous waste treatment & manual regeneration costs.

Dual-band UV degrades trace TOC, and vacuum degassing reduces dissolved oxygen to prevent pad oxidation. Ultra-precise terminal filters intercept ultrafine particles. All pipelines use EP-grade stainless steel and PVDF materials to avoid secondary ion contamination. A multi-parameter online monitoring system triggers automatic reflux protection for production lines upon abnormal water quality. The modular design supports direct expansion of RO and EDI modules for future capacity upgrades.

FacebookWhatsAppX